Description:
The function of the optical splitter is to divide a light source into 1*N lights path through the splitter reflection. It is also possible to synthesize 1*N lights path through a splitter to be recovered as a primary light source.The LGX box type PLC is packaged in an ABS plastic case and the port is end-to-end. Mainly installed in the fiber transfer box. We provide whole series of 1xN and 2xN splitter products that are tailored for specific applications. All products meet GR-1209-CORE and GR-1221-CORE requirements.
  • LGX ABS Fiber PLC Splitter with SC, LC Ports - Fiber Optical Supplier
  • LGX ABS Fiber PLC Splitter with SC, LC Ports - Fiber Optical Supplier
  • LGX ABS Fiber PLC Splitter with SC, LC Ports - Fiber Optical Supplier
Features:
  • Low Insertion loss
  • Low PDL
  • Compact Design
  • Good channel-to-channel uniformity
  • Wide Operating Wavelength:
  • From 1260nm to 1650nm
  • Wide Operating Temperature
  • High Reliability and Stability

Applications:
  • FTTX Systems
  • PON Networks
  • CATV Links
  • Optical Signal Distribution

Compliance
  • Telcordia GR-1209-CORE
  • Telcordia GR-1221-CORE

Specifications

Table 1 – 1×N PLC Splitter

Parameters

1×2

1×4

1×6

1×8

1×12

1×16

1×32

1×64

Operating Wavelength (nm)

1260~1650

Fiber Type

G657A or customer specified

Insertion Loss (dB)(Min/Max)

3.8/4.0

7.2/7.4

9.5/9.8

10.5/10.7

12.1/12.6

13.5/13.7

16.5/16.9

20.5/21.0

Loss Uniformity (dB)

0.6

0.6

1.0

0.8

1.1

1.2

1.5

2.5

Return Loss (dB)

55

55

55

55

55

55

55

55

Polarization Dependent Loss(dB)

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.4

Directivity (dB)

55

55

55

55

55

55

55

55

Operating Temperature(℃)

-40~+85

Storage Temperature(℃))

-40~+85

Operating Humidity

5% ~ 85% RH

Storage Humidity

5% ~ 85% RH

Device Dimension (mm)   (L×W×H)

40×4×4

40×4×4

40×4×4

40×4×4

50×4×4

50×4×4

50×7×4

60×12×4

Module Dimension (mm)   (L×W×H)

100×80×10

100×80×10

100×80×10

100×80×10

120×80×18

120×80×18

140×115×18

140×115×18

Mini-Module Dimension (mm)   (L×W×H)

50×7×4

50×7×4

60×7×4

60×7×4

60×12×4

60×12×4

80×20×6

N/A


Table 2 – 2×N PLC Splitter

Parameters

2×2

2×4

2×8

2×16

2×32

2×64

Operating Wavelength (nm)

1260~1650

Fiber Type

G657A or customer specified

Insertion Loss (dB)(Min/Max)

3.9/4.2

7.5/7.8

11.2/11.5

14.2/14.5

17.2/17.7

21.0/21.5

Loss Uniformity (dB)

0.8

1.5

1.5

1.8

2.0

2.5

Return Loss (dB)

55

55

55

55

55

55

Polarization Dependent Loss(dB)

0.2

0.2

0.4

0.4

0.4

0.4

Directivity (dB)

55

55

55

55

55

55

Operating Temperature(℃))

-40~+85

Storage Temperature(℃))

-40~+85

Operating Humidity

5% ~ 85% RH

Storage Humidity

5% ~ 85% RH

Device Dimension (mm)   (L×W×H)

40×4×4

50×4×4

50×4×4

50×7×4

60×7×4

60×12×4

Module Dimension (mm)   (L×W×H)

100×80×10

100×80×10

100×80×10

120×80×18

140×115×18

140×115×18

Mini-Module Dimension (mm)   (L×W×H)

60×7×4

60×7×4

60×7×4

60×12×4

80×20×6

N/A


Packaging & Shipping

Packaging & Shipping

Production

LGX ABS Fiber PLC Splitter with SC, LC Ports - Fiber Optical Supplier
Leave us Message EMAIL_US
Products
News
  • What is MTP/MPO Cabling System for Data Center?
    With the growth of data center high bandwidth demand, high speed becomes the trend of data center cabling system. Do you how to connect fiber optic cable? Using MTP/MPO components for MTP/MPO ca...
  • What is the difference between MPO and MTP?
    With the rapid development of data centers, cloud computing, cloud storage and other applications have gradually spread across various industries, and the bandwidth requirements for network communicat...
  • Application of MTP/MPO Fiber Cables in Data Center
    MTP/MPO fiber cables are widely used in data centers. In recent years, the demand for bandwidth of data center optical fiber transmission systems has shown a trend of high growth. Therefore, the use o...